If your dehumidifier is not collecting water even though the room temperature is over 65 degrees Fahrenheit, there might be an issue with the capacitor in the compressor circuit. The compressor circulates refrigerant through the unit to rerelocate moisture from the air, which collects in the bucket. If the capacitor falls short, the compressor will not run. Signs that the capacitor is defective are that the overfill device continually trips. A trained technician can percreate a test to determine if the capacitor is faulty.

You are watching: There is no water in this air


Back to Top

*
*
*

If your dehumidifier is not collecting water even though the room temperature is over 65 levels Fahrenheit, it most likely means that the dehumidifier compressor is not working. This part have the right to fail for a number of reasons, one of which is that the overfill tool has actually failed. The overfill is a component of the compressor which keeps the motor from coming to be damaged. If the overfill is not functioning, the compressor won’t work, meaning no water is being collected. The overfill deserve to be tested for continuity making use of a multi-meter. This component typically fails when the unit is powered by extension cords which are as well long or also tiny for the unit.


Back to Top

*

If your dehumidifier is not collecting water also though the room temperature is over 65 degrees Fahrenheit, tbelow may be a problem through the fan motor. The fan motor keeps the air flowing throughout the evaporator coils to save them from icing up. To troubleshoot this dehumidifier component, examine to see if there is air coming through the grille. If tright here is no air blowing or exceptionally little bit, inspect the fan cover and evaporator coils to make certain they aren’t blocked by dust and debris. Check to make certain the fan is able to revolve easily and that the blower wheel is secucount attached to the motor shaft. Sometimes the fan motor will revolve slowly, or hum but not revolve at all, meaning it needs to be reinserted. To observe the fan, you can operate the unit in fan just mode, however be incredibly cautious while doing this.


Back to Top

*

If your dehumidifier is not collecting water even though the room temperature is over 65 levels Fahrenheit, the digital manage board or PCB assembly might not be properly regulating the compressor and also fan motor. The manage board is a part on modern-day dehumidifiers, and also provides sensors to monitor the ambient humidity and also signal the compressor to begin. To troubleshoot this component, you have the right to perdevelop a voltage test on the output relays via a multi-meter to make sure the relays and also sensors are functioning.

See more: Who Is Tom Dacre And Why Does Tom Dacre Cry In The Chimney Sweeper Cry?


More Repair Parts

Still not certain which component is broken? We have the right to offer you practice troubleshooting assist if you search through your model number.